As we all know, good price and quality clamp on ultrasonic flow meter from China manufacturer is directly attached to the pipe wall. Do you know what kinds of installation methods are available? Today, I'd like to introduce the four installation methods of good price and quality clamp on ultrasonic flow meter from China manufacturer: V method, Z method, n method and W method. In general, V method is preferred for installing good price and quality clamp on ultrasonic flow meter when the pipe diameter is within dn15~200mm, Z method can be selected when the signal cannot be measured by V method or the signal quality is poor, and Z method is preferred when the pipe diameter is above dn200mm or when measuring cast iron pipe. N method and W method are rarely used, and are suitable for the installation of thin pipes below dn50mm.
1、 V-method installation of good price and quality clamp on ultrasonic flow meter from China manufacturer
In general, V method is a standard installation method for clamp on ultrasonic flow meter from China manufacturer, which is convenient to use and accurate to measure. During installation, the two sensors are aligned horizontally, in which the center line and the pipeline axis are horizontal, and the measurable pipe diameter range is dn15mm-dn400mm.
2、 Z-method installation of good price and quality clamp on ultrasonic flow meter from China manufacturer
When the pipeline is very thick or there are suspended solids in the liquid, the inner wall of the pipe is too thick or the lining is too thick, resulting in the weak signal of V method installation and the machine can not work normally, Z method installation is required. Z method is characterized by direct transmission of ultrasonic wave in the pipeline, no reflection (called single sound path) and small signal attenuation. The measurable pipe diameter range of Z method installation is 100mm to 6000mm. During the actual installation on site, it is recommended that pipes above 200mm should be installed by Z method.
3、 N-method installation of good price and quality clamp on ultrasonic flow meter from China manufacturer
The characteristic of n-method installation is to improve the measurement accuracy by extending the ultrasonic transmission distance. When the n method is used for installation, the ultrasonic beam is reflected twice in the pipe and passes through the fluid three times (called three sound paths), which is suitable for measuring small diameter pipes.
4、 Installation of good price and quality clamp on ultrasonic flow meter from China manufacturer by W method
Like n-method installation, w-method installation also improves the measurement accuracy of small pipe diameter by extending the ultrasonic transmission distance. W method installation is suitable for measuring small tubes below 50mm. When the W method is used for installation, the ultrasonic beam is reflected three times in the pipe and passes through the fluid four times (called four sound paths).


Professional manufacturer and exporter
of flowmeter equipment

Email:

Tel:

The Cross of 9th Avenue and 2th Longhai Road, Longting District, Kaifeng City, Henan Province, China.
HOT PRODUCTS
SEND US A MESSAGE
Email:
aylin18738997440@aliyun.com
WhatsApp:
+86-18738997440
Copyright © 2020 Kaifeng Baite Flow Instrument Co., Ltd.
豫ICP备20019609号
SEO