Requirements of customized alcohol turbine flow meter supplier china for external environment:
Requirements for impurities in the medium: in order to ensure the service life of the customized alcohol turbine flowmeter supplier china, a filter shall be installed in front of the straight pipe section of the customized alcohol turbine flow meter supplier china.
Installation site of customized alcohol turbine flow meter supplier china: alcohol turbine flowmeter shall be installed in a place convenient for maintenance and free of strong electromagnetic interference and heat radiation
Requirements for installation and welding of customized alcohol turbine flow meter supplier china: the user is equipped with another pair of standard flanges to be welded on the front and rear pipes. Welding with flowmeter is not allowed! Before installing the flowmeter, the pipeline with welding slag and other dirt diameter (or bypass pipe) shall be strictly removed to purge the pipeline instead of the flowmeter. To ensure that the flowmeter is not damaged during use. When installing the flow meter, the sealing gasket between flanges shall not be concave into the pipe.
Grounding requirements of customized alcohol turbine flowmeter supplier china: the alcohol turbine flowmeter shall be reliably grounded and cannot be shared with the grounding wire of strong current system.
Requirements of customized alcohol turbine flowmeter supplier china for explosion-proof products: for the safe and normal use of the instrument, the use environment of explosion-proof alcohol turbine flowmeter shall be rechecked to see whether it is consistent with the user's explosion-proof requirements, and the national explosion-proof product use requirements shall be strictly observed during installation and use. The user shall not change the connection mode of explosion-proof system or open the instrument at will. The selection shall be within the specified flow range to prevent overspeed operation, so as to ensure ideal accuracy and normal service life. Before installing the alcohol turbine flowmeter, the sundries in the pipeline shall be cleaned: debris, welding slag, stones, dust, etc. it is recommended to install a filter with 5 micron sieve at the upstream to block droplets and sand particles. When the alcohol turbine flow meter is put into operation, the front valve shall be opened first and then the rear valve shall be opened slowly to prevent the turbine from being damaged by instantaneous air flow impact. The lubricating oil shall be added according to the notice board, and the number of times of refueling depends on the cleanliness of the temperament, usually 2-3 times a year. Overspeed operation of the turbine caused by pressure test, purging pipeline or exhaust, and operation of the turbine in reverse flow may damage the flowmeter. It is not allowed to open the front flowmeter at will during operation Change the relevant internal parameters of the back cover, otherwise the normal operation of the flowmeter will be affected. Carefully install the gasket to ensure that no protrusions enter the pipe to prevent interference with normal flow measurement. When calibrating the alcohol turbine flow meter supplier china, the pressure shall be collected on the pressure tap of the flowmeter.


Professional manufacturer and exporter
of flowmeter equipment

Email:

Tel:

The Cross of 9th Avenue and 2th Longhai Road, Longting District, Kaifeng City, Henan Province, China.
HOT PRODUCTS
SEND US A MESSAGE
Email:
aylin18738997440@aliyun.com
WhatsApp:
+86-18738997440
Copyright © 2020 Kaifeng Baite Flow Instrument Co., Ltd.
豫ICP备20019609号
SEO